Trench depth shall be 30 inches minimum with or without gas service and greater if joint with a gas main.
Mobile home meter pole installation.
Hooking the home up to sewer lines and electric meters is not a simple diy project.
Street 36 min.
See below for our assembly guide for meter pole installation.
Pvc conduit to the home gray schedule 40 or.
All meter sockets shall be mounted in a manner that allows meters to be inserted and withdrawn.
Overhead service to.
Position pedestal so that electric meter is facing away from mobile home.
When one of these mobile homes need a wiring overhaul it is best to upgrade to 200 amp service.
This does not require you to replace every foot of wire in the mobile home.
Install on side of pole opposite service drop.
Three metal conduit straps minimum one near top one mid way and one within a foot of the meter socket.
Position pedestal so that electric meter is facing away from mobile home towards right of way.
No joints above or within 2 feet of top of pole.
Alternate location for pedestal.
Eaton s versatile mobile home panels have a user friendly design that allows for a faster cleaner installation.
Metering installations for mobile homes or mobile home parks.
If metallic weather head is used with pvc conduit it must have a bonding ground.
To do the rest of the work.
With that said try finding a moving company that can will handle all aspects of installation.
25 foot pole no disconnect or meter base overhead service bare pole only 360 00.
It is also suitable for service entrance equipment.
The mhm200p is 200 amp unit and is designed with ample width to ensure plenty of room for wire bending and an easier installation.
Some moving companies will only go so far to transport your mobile home and leave it to you to find a plumber electrician etc.
Pole with meter base and 240v 200 amp disconnect.
Overhead installations the metering pole must be a minimum of 17 ft class 5 pole set at least 4 ft deep so that it will be of sufficient height and stability to provide service drop clearances as shown on page 31.
Overhead service to mobile home.
5 1 2 from ground to center of meter mobile home poles and must be within 24 of eyebolt minimum of 12 heighth to weatherhead 200 amp.
Use 2 0 thw hotlegs with minimum 18 tails for connection tvec will spot all mobile home poles 1 neutral stranded copper meter base unbroken for connection galvanized steeples or wire holding.
25 foot meter poles and fused disconnect poles.
Meter base mounted on exterior wall of house or mobile manufactured home.
Two ft of conduit above pole.
Pole with 480v 30 amp disconnect.