The run from shower drain to the trap would be about 4 feet.
Minimum floor joist depth below shower drain and p trap.
You attach the p trap directly to the drainage and manuever the p traps exits into you existing drain.
Is there a problem if i run an 8 section of drain pipe to a.
I ve contemplated using 1 5 p trap.
Drain piping upc 708 0 and vent pipe upc 905 1 not to grade drain piping can be horizontal 1 4 per foot vertical or 450 vent piping shall be free of sags and be graded.
Set the shower base in place to double check the final placement of the p trap inserting a short temporary tailpiece.
Shower drain trap 1 answers i have removed a bathtub and i m replacing with a shower.
Bath shower drain flat p trap 1 1 2 with flexible pipe e015 p trap for acrylic bathtubs by aniplast.
The offset outlet is located 8 20 3 cm from the edge of the channel body and provides flexibility when obstacles e g floor joists are encountered during installation.
If i install a trap inside the house proper a running trap freezing will not be an issue.
The shower tile installer asked that the new drain be placed in the middle of the floor.
The outlet side of the p trap is flush against the bathroom floor decking along with the drain pipe it connects to the wye the 1 5 dwv pipe so no more room to gain there.
4 8 out of 5 stars 52.
In stock on october 14 2020.
Cement it together and quickly plumb the p trap with a 6 in.
Get it as soon as fri oct 9.
Use reference marks on the subfloor to fine tune the location of the drain.
It can also be lower than your exit pipe you need to drain into.
There is a heating duct that prevents placing the drain trap directly under the drain.
Problem is the p trap almost touches the bottom of the joist cavity and is likely to freeze being very close to the exterior of the house.
Free shipping by amazon.
Bluevue 1 5 side outlet drain assembly.
Well this doesn t really matter and is totally dependent on the trap outlet height.
Save the p trap to drain line connection for last.
It is not ideal to have the p trap below the the exit drain because water gravity has to force the water out instead of it flowing downwards naturally.
The trap outlet distance is regulated based on the pipe diameter and i am sure this has been answered many times on here.
Level before the joint sets.
This could be 6 inches or 2 feet.
Kerdi line includes a corresponding polystyrene foam channel support to set the drain elevation to the corresponding kerdi shower lt lts shower trays.
Depends on where your trap outlet comes out of wall or meets below floor.