Anything that a person might need to reach should be a maximum of 48 1220 mm.
Minimum ada toilet stall size.
Horizontal grab bars must be installed behind the toilet and on the nearest wall or partition whichever is closer.
Dimension guidelines when dispensers protrude from the wall in toilet rooms and toilet compartments.
There are many dimensions to consider when designing an accessible bathroom stall.
The minimum width of the stall is 60 inches 1525 mm.
An example of a single ada bathroom layout.
The space can provide forward or parallel access to the bathroom equipment and part of the area can underneath the equipment as long as there is enough clearance for the knees and toes of the person in the wheelchair.
Figure 30 a standard stall.
The centerline of the water closet is 18 inches 455 mm from the side wall.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
Where toilet rooms are provided in multi story facilities that are exempt from the requirement for vertical access between stories 206 2 3 ex.
Distances should allow for common usage by people with a limited range of motion.
7 0 x 5 0 35 00 square feet.
The required minimum floor space for a handicapped accessible bathroom is 30 inches by 48 inches.
However stall depth can be anywhere between 48 inches to 78 inches as needed.
Accessible toilet stalls or compartments must have a minimum width of 60 inches and sufficient space to accommodate a wheelchair to the sides of the toilet or in front of it.
The room would be larger if the door were in swinging.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
Figure 30 a standard stall.
The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm.
The minimum width of the stall is 60 inches 1525 mm.
1 or 2 a toilet room must be provided on a story that is connected to an accessible entrance by an accessible route 213 1.
This plan shows a typical example of a single user toilet room that meets the minimum requirements of the 2010.
Multiple toilet stall layouts.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
The standards specify the location of toilet rooms in two instances.
Standard bathroom stall sizes rarely vary and tend to be 36 inches wide and 60 inches deep.